Table 2-1 Description on the fields of the display poe-power ac-input state
command
Field Description
Normal: The AC input is normal.
Lack Phrase: The PSU is idle.
Under Limit: The AC input voltage is lower than
the lower threshold.
Upper Limit: The AC input voltage is higher than
the upper threshold.
Fuse Broken: The fuse is blown.
PSU 1 AC Input State:
(AC input state of PoE PSU 1)
Switch Off: The switch is off.
2.1.2 display poe-power alarm
Syntax
display poe-power alarm
View
Any view
Parameter
None
Description
Use the display poe-power alarm command to display the detailed alarm information
about the external PoE PSUs.
Example
# Display the detailed alarm information about the external PoE PSUs.
<Quidway> display poe-power alarm
PSU alarm detail:
Number of PSUs : 3
PSU 1 : Absent
PSU 2 : NORMAL Normal.
PSU 3 : Absent

Table of Contents

Other manuals for Huawei Quidway S6500 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei Quidway S6500 Series and is the answer not in the manual?

Huawei Quidway S6500 Series Specifications

General IconGeneral
BrandHuawei
ModelQuidway S6500 Series
CategoryNetwork Router
LanguageEnglish

Related product manuals