Command Manual - System Management
Quidway S6500 Series Ethernet Switches Chapter 6 RMON Configuration Commands
Huawei Technologies Proprietary
6-10
log-trap: Log and trap event.
log-trapcommunity: The name of the community that trap message is sent to.
none: neither log nor trap event.
owner rmon-station: The name of the network management station that creates this
entry. The length of the character string ranges from 1 to 127.
Description
Using rmon event command, you can add an entry to the event table. Using undo
rmon event command, you can cancel an entry from this table.
Event management of RMON defines the way to deal with event number and event-log,
send trap message or log while sending trap message. In this way, alarm events may
obtain corresponding treatment
Example
# Add the entry 10 to the event table and marks it as log event.
[Quidway] rmon event 10 log
6.1.9 rmon history
Syntax
rmon history entry-number buckets number interval interval [ owner text ]
undo rmon history entry-number
View
Ethernet port view
Parameter
entry-number: Number of the entry to be added/deleted, ranging from 1 to 65535.
buckets number: Capacity of the history table corresponding to the control line.
interval: Sampling interval, ranging from 5 to 3600 (measured in seconds).
text: Creator of the line. Length of the character string ranges from 1 to127.
Description
Using rmon history command, you can add an entry to the history control table. Using
undo rmon history command, you can cancel an entry from history control table.
Perform this command to sample, set sample parameter (sample time interval) and
storage amounts for a port. RMON will periodically perform data collection and save for
query on this port. Sample information includes utility, error number and total packet
number.