Command Manual - Getting Started
Quidway S6500 Series Ethernet Switches Chapter 1 Logging in Ethernet Switch Commands
Huawei Technologies Proprietary
1-24
level to a higher level. For the sake of confidentiality, on the screen the user cannot see
the password that he entered. Only when correct password is input for three times, can
the user switch to the higher level. Otherwise, the original user level will remain
unchanged. Using undo super password command, you can cancel the current
settings.
The password in plain text is required when performing authentication, regardless
whether the configuration is plain text or encrypted text.
Example
# Configure the password to zbr for changing the user from the current level to level 3.
[Quidway] super password level 3 simple zbr
1.1.31 sysname
Syntax
sysname text
undo sysname
View
System view
Parameter
text: Specifies the hostname with a character string, ranging from 1 to 30 characters.
The default name is Quidway.
Description
Using sysname command, you can configure the hostname of the Ethernet switch.
Using undo sysname command, you can restore the default hostname.
Changing the hostname of the Ethernet switch will affect the prompt of command line
interface. For example, if the hostname of the Ethernet switch is Quidway, the prompt in
user view will be <Quidway>.
Example
# Configure the hostname of Ethernet switch to Huawei.
[Quidway] sysname Huawei
[Huawei]
1.1.32 system-view
Syntax
system-view