Command Manual - System Management
Quidway S6500 Series Ethernet Switches Chapter 3 Device Management Commands
Huawei Technologies Proprietary
3-17
that day; if the configured time is before the current time, the switch will be restarted at
the time point of the next day.
It should be noted that the configured date should not exceed the current date more
than 30 days. In addition, after the command is configured, the system will prompt you
to input confirmation information. Only after the "Y" or the "y" is entered can the
configuration be valid. If there is related configuration before, it will be covered directly.
Moreover, after the schedule reboot at command is configured and the system time is
adjusted by the clock command, the former configured schedule reboot at parameter
will go invalid.
For the related command, see reboot, schedule reboot delay, display schedule reboot.
Example
# Set the switch to be restarted at 22:00 that night ( the current time is 16:21 ).
<Quidway> schedule reboot at 22:00
Reboot system at 22:00 2005/04/06(in 5 hours and 39 minutes)
confirm?[Y/N]:y
<Quidway>
%Apr 6 16:21:03 2005 S6506R CMD/5/REBOOT:
aux0: schedule reboot parameters at 16:21:00 2005/04/06. And system will reboot
at 22:00:2005 04/06/2005.
3.1.23 schedule reboot delay
Syntax
schedule reboot delay { hhh:mm | mmm }
undo schedule reboot
View
User view
Parameter
hhh:mm: Waiting time for rebooting a switch, in the format of "hour: minute" The hhh
ranges from 0 to 720, and the mm ranges from 0 to 59.
mmm: Waiting delay for rebooting a switch, in the format of "absolute minutes" .
Ranging from 0 to 43200,
Description
Using the schedule reboot delay command, you can enable the timing reboot switch
function and set the waiting time. Using the undo schedule reboot command, you can
disable the timing reboot function.