Command Manual - System Management 
Quidway S6500 Series Ethernet Switches  Chapter 6  RMON Configuration Commands
 
Huawei Technologies Proprietary 
6-6 
Description 
Using display rmon prialarm command, you can view information about extended 
alarm table. 
For the related commands, see rmon prialarm. 
Example 
# display alarm information about extended RMON.  
<Quidway> display rmon prialarm 
Prialarm table 1 owned by abc is VALID. 
  Samples type          : delta 
  Variable formula      : .1.3.6.1.2.1.2.2.1.10.641 
  Description           : ifInOctets.Ethernet1/0/1 
  Sampling interval     : 10(sec) 
  Rising threshold      : 100(linked with event 2) 
  Falling threshold     : 10(linked with event 2) 
  When startup enables  : risingOrFallingAlarm 
  This entry will exist : forever. 
  Latest value          : 0 
Table 6-5 Output description of the display rmon prialarm command 
Field  Description 
Prialarm table 1  Index of extended alarm entry 
owned by abc  Creator of the extended alarm entry 
VALID  The entry corresponding to the index is valid. 
Samples type  The sampling type 
Variable formula   The variable formula of the node 
Description The description of the alarm variable 
Rising threshold 
Rising threshold. When sampling value rises from 
normal value to this threshold, rising threshold alarm 
will be triggered.  
Falling threshold 
Falling threshold. When sampling value decreases from 
normal value to this threshold, falling threshold alarm 
will be triggered. 
linked with event 2 
Corresponding event index of ring and falling threshold 
alarm 
When startup enables: 
risingOrFallingAlarm  
Kind of first alarm. It may trigger rising threshold alarm 
or falling threshold alarm or both. 
This entry will exist 
forever 
The lifespan of this alarm entry which can be forever or 
a specified period of time.