EasyManua.ls Logo

R&S ZNB Series - Page 1140

R&S ZNB Series
1611 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Command reference
R&S
®
ZNB/ZNBT
1140User Manual 1173.9163.02 ─ 62
MMEMory:STORe:CORRection.....................................................................................1167
MMEMory:STORe:CORRection:TCOefficient<Ch>.......................................................... 1168
MMEMory:STORe:EYE:MASK.......................................................................................1168
MMEMory:STORe:EYE:MASK:RESults.......................................................................... 1169
MMEMory:STORe:EYE:MEASurements......................................................................... 1169
MMEMory:STORe:LIMit................................................................................................ 1170
MMEMory:STORe:MARKer...........................................................................................1170
MMEMory:STORe:RIPPle............................................................................................. 1171
MMEMory:STORe:SEGMent......................................................................................... 1171
MMEMory:STORe:STATe..............................................................................................1172
MMEMory:STORe:TRACe.............................................................................................1172
MMEMory:STORe:TRACe:CHANnel.............................................................................. 1173
MMEMory:STORe:TRACe:OPTion:BALanced................................................................. 1175
MMEMory:STORe:TRACe:OPTion:SYMMetric................................................................ 1175
MMEMory:STORe:TRACe:OPTion:COMMent................................................................. 1175
MMEMory:STORe:TRACe:OPTion:DECimals:DATA........................................................ 1175
MMEMory:STORe:TRACe:OPTion:DECimals:STIMulus................................................... 1175
MMEMory:STORe:TRACe:OPTion:FORMat....................................................................1176
MMEMory:STORe:TRACe:OPTion:PLUS....................................................................... 1176
MMEMory:STORe:TRACe:OPTion:SSEParator...............................................................1176
MMEMory:STORe:TRACe:OPTion:TABS........................................................................1176
MMEMory:STORe:TRACe:OPTion:TRIM........................................................................ 1177
MMEMory:STORe:TRACe:PORTs................................................................................. 1177
MMEMory:AKAL:FACTory:CONVersion <Directory>
Converts the factory calibration data of the standards in the active calibration unit
(SYSTem:COMMunicate:RDEVice:AKAL:ADDRess) to Touchstone format and cop-
ies it to the specified directory.
Setting parameters:
<Directory> String parameter to specify the directory.
Example:
MMEM:AKAL:FACTory:CONVersion 'C:\Users\Public\
Documents\Rohde-Schwarz\Vna\AKAL\Touchstone'
Convert and copy the factory calibration data of the active cali-
bration unit to the specified (writable) directory.
Usage: Setting only
Manual operation: See "Apply/Cancel" on page 458
MMEMory:AKAL:USER:CONVersion <Directory>[, <CalKitFile>]
Converts an arbitrary (e.g. user-defined) set of calibration data of the standards in the
active calibration unit (SYSTem:COMMunicate:RDEVice:AKAL:ADDRess) to Touch-
stone format and copies it to the specified directory.
Setting parameters:
<Directory> String parameter to specify the directory.
<CalKitFile>
SCPI command reference

Table of Contents

Related product manuals