14 :DVM Commands
:DVM:MODE
(see page 1138)
Command Syntax
:DVM:MODE <dvm_mode>
<dvm_mode> ::= {ACRMs | DC | DCRMs | FREQuency}
The :DVM:MODE command sets the digital voltmenter (DVM) mode:
• ACRMs — displays the root-mean-square value of the acquired data,
with the DC component removed.
• DC — displays the DC value of the acquired data.
• DCRMs — displays the root-mean-square value of the acquired data.
• FREQuency — displays the frequency counter measurement.
Query Syntax
:DVM:MODE?
The :DVM:MODE? query returns the selected DVM mode.
Return Format
<dvm_mode><NL>
<dvm_mode> ::= {ACRM | DC | DCRM | FREQ}
See Also • ":DVM:ENABle" on page 312
• ":DVM:SOURce" on page 315
• ":DVM:ARANge" on page 310
• ":DVM:CURRent" on page 311
• ":DVM:FREQuency" on page 313

Table of Contents

Other manuals for Agilent Technologies InfiniiVision 3000 X-Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies InfiniiVision 3000 X-Series and is the answer not in the manual?

Agilent Technologies InfiniiVision 3000 X-Series Specifications

General IconGeneral
BrandAgilent Technologies
ModelInfiniiVision 3000 X-Series
CategoryTest Equipment
LanguageEnglish

Related product manuals