4. Attach the CLUTCH FIX PLATE to the ADF BASE matching the positioning
hole of the CLUTCH FIX PLATE with the guide pin of the ADF BASE, and
secure the CLUTCH FIX PLATE with the two screws (M3 x 8 mm, P-type, A-
head). See Figure 4-188.
5. Secure the harnesses of the MAGNETIC CLUTCH into the notch of the ADF
BASE. See Figure 4-186.
6. Attach the GEAR 20T to the TRANSFER SHAFT. See Figure 4-185.
7. Attach the ADF BASE ASSY. (p498)
8. Attach the ADF COVER C. (p496)
9. Attach the ADF COVER R. (p492)
10. Attach the ADF Unit. (p481)
11. Install the Scanner. (p306)
Figure 4-188. Reinstallation of E CLUTCH UNIT
CLUTCH FIX PLATE Positioning Hole and Guide Pin