EPSON AcuLaser CX11/CX11F Revision B
APPENDIX Fax Unit System 652
COM_V34_SHIFT_G3 310 019
---
0B0
Enables or disables shifting to G3 mode when V34_CC time-out
occurs.
Set whether shift or not to shift to usual G3 mode when
COM_V34_CC_TIME time-out occurs.
If this is set to shift to G3 mode, it may happen to infringe
certain patent.
0 = Not allow
1 = Allow
Not allow
(0)
---
COM_V34_ENABLE 310 020
---
0B1
Enables or disables the V.34 ability
Set whether enables or disables V.34 performance regarding the
modulation method.
0 = Disable
1 = Enable
Enable
(1)
---
COM_ANSAM_TX_TIME 310 021
---
0B2
ANSam signal maximum transmitting time 0.1 to 25.5 sec (1 step = 100 ms) 4.0 seconds
(40)
---
COM_ANSAM_START_DELAY 310 022
---
0B3
Time interval until ANSam signal is transmitted
Set the time interval to start transmitting ANSam signal after the
line gets disconnected.
0.1 to 25.5 sec (1 step = 100 ms) 2.2 seconds
(22)
---
COM_V34_FRAME_SIZE 310 023
---
0B4
Frame size when transmitting V.34
0 = 256 octets
1 = 64 octets
256 octets
(0)
---
COM_ECM_ENABLE 310 024
---
0B5
Enables or disables the ECM performance (auto resending
function)
When line fault occurs in the middle of sending a fax, the function
allows the fax to be resend automatically immediately after the line
is restored.
0 = Disable
1 = Enable
Enable
(1)
---
COM_RTN_TX_RATE 310 034
---
0B6
RTN command transmitting criterion (percentage)
RTN: Indicates that training is required because messages are not
received correctly.
0 to 100 % (1 step = 1%)
5%
(5)
---
COM_RTN_TX_LINE 310 035
---
0B7
RTN command transmitting criterion (number of continuous lines) 0 to 255 lines (1 step = 1 line)
5 lines
(5)
---
COM_T1_TIME_CALL 310 036
---
0B8
T1 timer immediately after dialing 0 to 255 sec (1 step = 1 sec) 50 seconds
(50)
---
COM_T1_TIME_TX 310 037
---
0B9
T1 timer when transmitting a fax 0 to 255 sec (1 step = 1 sec) 36 seconds
(36)
---
COM_T1_TIME_RX 310 038
---
0BA
T1 timer when receiving a fax 0 to 255 sec (1 step = 1 sec) 39 seconds
(39)
---
COM_T2_TIME 310 039
---
0BB
T2 timer 0 to 25.5 sec (1 step = 100 ms) 6 seconds
(60)
---
COM_T3_TIME 310 040
---
0BC
T3 timer 0 to 25.5 sec (1 step = 100 ms) 15 seconds
(150)
---
Table 7-19. List of System Parameter (Communication Control)
Label
Maintenanc
e Code
User
Access
Internal
Address
Description Setting Value Default
Remark
s