EPSON AcuLaser CX11/CX11F Revision B
APPENDIX Fax Unit System 667
300 064 0x3040
Receiving the fax is rejected due to the DM prevention
function
Not used --- --- --- --- ---
300 065 0x3041
The product failed to read the original while
performing manual transmitting
The next original was not
set in time
Try the operation again *3 External error code 50H: Forced stop Transmitting a fax is finished
300 066 0x3042
When transmitting, image data conversion was not
made in time
MFP data transferring
failure
External error code 50H: Forced stop Transmitting a fax is finished
300 100 0x3100
The product could not detect normal lines within a
minute after starting to receive the image data in G3
mode
Not used --- --- --- --- ---
300 101 0x3101
Decoding data without RTC at the time of ECM
reception caused the MN8604 to be disabled to perform
decode process
Not used --- --- --- --- ---
300 102 0x3102
Number of lines for received one page exceeded
acceptable level (more than 65535 lines)
Not used --- --- --- --- ---
300 103 0x3103
Abnormal termination of MN86064 Not used
300 104 0x3104
MN8604 failed to process commands within a
prescribed time period
Not used --- --- --- --- ---
300 105 0x3105
File pointer that is used for writing/reading in
encoding/decoding process caused an error
There is something wrong
with the fax board or the
S/W
Replace the fax board --- Transmitting failure 50H: Forced stop Transmitting a fax is finished
300 106 0x3106
The number of lines that indicate the processed lines in
encoding/decoding process is 0
There is something wrong
with the fax board or the
S/W
Replace the fax board --- Transmitting failure 50H: Forced stop Transmitting a fax is finished
300 107 0x3107
Monitor timer for encoding/decoding by MN86064
became time-out
Not used --- --- --- --- ---
300 108 0x3108
Target file is empty in decoding/encoding process Not used --- --- --- --- ---
300 109 0x3109
During MMR decoding, MN86064 decode error
occurred
Not used --- --- --- --- ---
300 110 0x310A
During decoding JBIG data at MN86064, BIH/over
flow error was detected
Not used --- --- --- --- ---
300 111 0x310B
During decoding JBIG data at MN86064, an end
marker error was detected
Not used --- --- --- --- ---
300 112 0x310C
During decoding JBIG data at MN86064, a YD error
was detected
Not used --- --- --- --- ---
300 113 0x310D
During decoding JBIG data at MN86064, an abort
marker error was detected
Not used --- --- --- --- ---
300 114 0x310E
During decoding JBIG data, BIH operated abnormally Not used --- --- --- --- ---
Table 7-23. Operator Call Error
External
error code
Internal
Code
Description Cause Remedies
Panel
Display
(reference)
Report Display
Trigger for
Stopping
Operation
Notification Message
MAIN SUB