Command Manual - HWPing
Quidway S3900 Series Ethernet Switches-Release 1510 Chapter 1 HWPing Commands
Huawei Technologies Proprietary
1-4
Field Description
Operation timeout number
Number of times of timeouts in the test
operation
System busy operation number
Number of times the test fails because
the system is busy
Connection fail number Number of connection failures
Operation sequence errors
Number of received sequence error
packets
Drop operation number
Number of system resource allocation
errors
Other operation errors Number of other errors
# Use the display hwping history command to display test results.
<Quidway> display hwping history administrator icmp
HWPing entry(admin administrator, tag icmp) history record:
Index Response Status LastRC Time
1 1 1 0 2004-11-25 16:28:55.0
2 1 1 0 2004-11-25 16:28:55.0
3 1 1 0 2004-11-25 16:28:55.0
4 1 1 0 2004-11-25 16:28:55.0
5 1 1 0 2004-11-25 16:28:55.0
6 2 1 0 2004-11-25 16:28:55.0
7 1 1 0 2004-11-25 16:28:55.0
8 1 1 0 2004-11-25 16:28:55.0
9 1 1 0 2004-11-25 16:28:55.9
10 1 1 0 2004-11-25 16:28:55.9
Table 1-2 Description on the fields of the display hwping history command
Field Description
Index Index of the displayed information
Response
Round trip test time, in milliseconds, or the timeout time.
0 means the test fails.