126 Agilent InfiniiVision 3000 X-Series Oscilloscopes Programmer's Guide
4 Commands Quick Reference
:SBUS<n>:LIN:TRIGger:
PATTern:DATA <string>
(see page 727)
:SBUS<n>:LIN:TRIGger:
PATTern:DATA? (see
page 727)
<string> ::= "n" where n ::=
32-bit integer in unsigned
decimal when <base> = DECimal
<string> ::= "nn...n" where n ::=
{0 | 1 | X | $} when <base> =
BINary
<string> ::= "0xnn...n" where n
::= {0,..,9 | A,..,F | X | $}
when <base> = HEX
:SBUS<n>:LIN:TRIGger:
PATTern:DATA:LENGth
<length> (see
page 729)
:SBUS<n>:LIN:TRIGger:
PATTern:DATA:LENGth?
(see page 729)
<length> ::= integer from 1 to 8
in NR1 format
:SBUS<n>:LIN:TRIGger:
PATTern:FORMat <base>
(see page 730)
:SBUS<n>:LIN:TRIGger:
PATTern:FORMat? (see
page 730)
<base> ::= {BINary | HEX |
DECimal}
Table 29 :SBUS<n>:LIN Commands Summary (continued)
Command Query Options and Query Returns
Table 30 :SBUS<n>:M1553 Commands Summary
Command Query Options and Query Returns
:SBUS<n>:M1553:AUTose
tup (see page 732)
n/a n/a
:SBUS<n>:M1553:BASE
<base> (see page 733)
:SBUS<n>:M1553:BASE?
(see page 733)
<base> ::= {BINary | HEX}
:SBUS<n>:M1553:SOURce
<source> (see
page 734)
:SBUS<n>:M1553:SOURce
? (see page 734)
<source> ::= {CHANnel<n>}
<n> ::= 1 to (# analog channels)
in NR1 format
:SBUS<n>:M1553:TRIGge
r:PATTern:DATA
<string> (see
page 735)
:SBUS<n>:M1553:TRIGge
r:PATTern:DATA? (see
page 735)
<string> ::= "nn...n" where n ::=
{0 | 1 | X}
:SBUS<n>:M1553:TRIGge
r:RTA <value> (see
page 736)
:SBUS<n>:M1553:TRIGge
r:RTA? (see page 736)
<value> ::= 5-bit integer in
decimal, <nondecimal>, or
<string> from 0-31
<nondecimal> ::= #Hnn where n ::=
{0,..,9|A,..,F}
<string> ::= "0xnn" where n::=
{0,..,9|A,..,F}
:SBUS<n>:M1553:TRIGge
r:TYPE <type> (see
page 737)
:SBUS<n>:M1553:TRIGge
r:TYPE? (see
page 737)
<type> ::= {DSTArt | DSTOp |
CSTArt | CSTOp | RTA | PERRor |