Commands Quick Reference 4
Agilent InfiniiVision 3000 X-Series Oscilloscopes Programmer's Guide 95
:MARKer:XUNits:USE
(see page 388)
n/a n/a
:MARKer:Y1Position
<position>[suffix]
(see page 389)
:MARKer:Y1Position?
(see page 389)
<position> ::= Y1 cursor position
value in NR3 format
[suffix] ::= {V | mV | dB}
<return_value> ::= Y1 cursor
position value in NR3 format
:MARKer:Y2Position
<position>[suffix]
(see page 390)
:MARKer:Y2Position?
(see page 390)
<position> ::= Y2 cursor position
value in NR3 format
[suffix] ::= {V | mV | dB}
<return_value> ::= Y2 cursor
position value in NR3 format
n/a :MARKer:YDELta? (see
page 391)
<return_value> ::= Y cursors
delta value in NR3 format
:MARKer:YUNits <mode>
(see page 392)
:MARKer:YUNits? (see
page 392)
<units> ::= {BASE | PERCent}
:MARKer:YUNits:USE
(see page 393)
n/a n/a
Table 16 :MARKer Commands Summary (continued)
Command Query Options and Query Returns
Table 17 :MEASure Commands Summary
Command Query Options and Query Returns
:MEASure:ALL (see
page 408)
n/a n/a
:MEASure:AREa
[<interval>][,][<sour
ce>] (see page 409)
:MEASure:AREa?
[<interval>][,][<sour
ce>] (see page 409)
<interval> ::= {CYCLe | DISPlay}
<source> ::= {CHANnel<n> |
FUNCtion | MATH | WMEMory<r>}
<n> ::= 1 to (# analog channels)
in NR1 format
<r> ::= 1-2 in NR1 format
<return_value> ::= area in
volt-seconds, NR3 format
:MEASure:BWIDth
[<source>] (see
page 410)
:MEASure:BWIDth?
[<source>] (see
page 410)
<source> ::= {CHANnel<n> |
FUNCtion | MATH | WMEMory<r>}
<n> ::= 1 to (# analog channels)
in NR1 format
<r> ::= 1-2 in NR1 format
<return_value> ::= burst width in
seconds, NR3 format
:MEASure:CLEar (see
page 411)
n/a n/a