Sequence Times - Main Times (in/out/delay/wait)
Times are set to the step in A (Active) or B (Next) depending on the setting for times (SETUP &
TIME).
Function Key Feedback
In time
[#] [IN]
A time is set for the
incoming channels.
Out time
[#] [OUT]
A time is set for the
outgoing channels.
In- and Out time
[#] [TIME]
A time is set for the in- and
outgoing channels.
Delay In time
[#] [DELAY] & [IN]
A delay time is set for the
incoming channels.
Delay Out time
[#] [DELAY] &
[OUT]
A delay time is set for the
outgoing channels.
Wait, Followon or
Alert time *
Sequences - Sequence
List
Enter the time in the WFA
Time column of the
Sequence List. You can
toggle between Wait, Alert
or Followon in the previous
column
* A Wait or Followon time will automatically execute a crossfade to the Step it is assigned to. The
difference is that a Wait time starts counting down after the END of the previous crossfade, while the
Followon time starts counting down from the START of the previous crossfade. Wait times is the
default setting. The Alert time will count down as a warning to the operator, but not execute the next
fade. See Sequence Times - Alert Times
.
See Times Soft Key Page
.