Operation Manual – Port Basic Configuration
H3C S3600 Series Ethernet Switches-Release 1510 Chapter 1 Port Basic Configuration
1-11
1.2.10 Enabling the System to Test Connected Cable
You can enable the system to test the cable connected to a specific port. The test result
will be returned in five seconds. The system can test these attributes of the cable:
Receive and transmit directions (RX and TX), short circuit/open circuit or not, the length
of the faulty cable.
Table 1-12 Enable the system to test connected cables
Operation Command Remarks
Enter system view
system-view
Enter Ethernet port view
interface interface-type
interface-number
Enable the system to test
connected cables
virtual-cable-test
Required
1.2.11 Configuring the Interval to Perform Statistical Analysis on Port Traffic
By performing the following configuration, you can set the interval to perform statistical
analysis on the traffic of a port.
When you use the display interface interface-type interface-number command to
display the information of a port, the system performs statistical analysis on the traffic
flow passing through the port during the specified interval and displays the average
rates in the interval. For example, if you set this interval to 100 seconds, the displayed
information is as follows:
Last 100 seconds input: 0 packets/sec 0 bytes/sec
Last 100 seconds output: 0 packets/sec 0 bytes/sec
Table 1-13 Set the interval to perform statistical analysis on port traffic
Operation Command Description
Enter system view
system-view
Enter Ethernet port view
interface interface-type
interface-number
Set the interval to perform
statistical analysis on port
traffic
flow-interval interval
Optional
By default, this interval is
300 seconds.
1.2.12 Enabling Giant-Frame Statistics Function
The giant-frame statistics function is used to ensure transmission of network traffic and
to facilitate statistics and analysis of unusual traffic on the network.

Table of Contents

Other manuals for H3C S3600 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the H3C S3600 Series and is the answer not in the manual?

H3C S3600 Series Specifications

General IconGeneral
BrandH3C
ModelS3600 Series
CategorySwitch
LanguageEnglish

Related product manuals