Operation Manual – MSTP
H3C S3600 Series Ethernet Switches-Release 1510 Chapter 1
MSTP Configuration
1-35
and forward any BPDU packets. In this way, the switch is protected again the BPDU
packet attack so that the STP calculation is assured to be right.
1.5.2 Configuration Prerequisites
MSTP runs normally on the switch.
1.5.3 Configuring BPDU Protection
I. Configuration procedure
Table 1-30 Configure BPDU protection
Operation Command Description
Enter system view
system-view
—
Enable the BPDU
protection function
stp
bpdu-protection
Required
The BPDU protection function
is disabled by default.
II. Configuration example
# Enable the BPDU protection function.
<H3C> system-view
[H3C] stp bpdu-protection
Caution:
As Gigabit ports of an S3600 Ethernet switch cannot be shut down, the BPDU
protection function is not applicable to these ports even if you enable the BPDU
protection function and specify these ports to be MSTP edge ports.
1.5.4 Configuring Root Protection
I. Configuration procedure
Table 1-31 Configure the root protection function in system view
Operation Command Description
Enter system view
system-view
—