Operation Manual – Information Center
H3C S3600 Series Ethernet Switches-Release 1510 Chapter 1
Information Cente
r
1-7
Note:
z After the switches form a fabric, you can use the info-center switch-on command
to enable the information output for the switch to make the log, debugging and trap
information of each switch in the fabric synchronous. Each switch sends its own
information to other switches in the fabric and receives information sent by other
switches at the same time to update the information on itself. In this way, the switch
ensures the synchronization of log, debugging and trap information in the whole
fabric.
z To view the debugging information of specific modules, you need to set the
information type as debug in the info-center source command, and enable
debugging for corresponding modules through the debugging command.
1.2.3 Enabling Information Output to the Console
Table 1-6 lists the related configurations on the switch.
Table 1-6 Enable information output to the console
Operation Command Description
Enter system view
system-view
Enable the
information center
info-center enable
Optional
By default, the information
center is enabled.
Enable information
output to the
console
info-center console
channel { channel-number |
channel-name }
Required
By default, the switch uses
information channel 0 to
output log/debugging/trap
information to the console.
Define an
information source
info-center source
{ modu-name | default }
channel { channel-number |
channel-name } [ { log | trap
| debug } { level severity |
state state } ]*
Required
Set the format of
time stamp
info-center timestamp { log
| trap | debugging } { boot |
date | none }
Optional
To view log/debugging/trap output information on the console, you should also enable
the corresponding log/debugging/trap information terminal display on the switch.

Table of Contents

Other manuals for H3C S3600 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the H3C S3600 Series and is the answer not in the manual?

H3C S3600 Series Specifications

General IconGeneral
BrandH3C
ModelS3600 Series
CategorySwitch
LanguageEnglish

Related product manuals