Operation Manual – System Maintenance and Debugging
H3C S3600 Series Ethernet Switches-Release 1510
Chapter 2 Basic System Configuration
& Debugging
2-6
2.3.2 Displaying Debugging Status
Table 2-12 Display the current debugging status in the system
Operation Command Description
Display all enabled
debugging on the
specified device
display debugging { fabric |
unit unit-id } [ interface
interface-type interface-number
| module-name ]
Display all enabled
debugging in the Fabric by
module
display debugging fabric
by-module
You can execute
the display
command in any
view.
2.3.3 Displaying Operating Information about Modules in System
When an Ethernet switch is in trouble, you may need to view a lot of operating
information to locate the problem. Each functional module has its corresponding
operating information display command(s). You can use the command here to display
the current operating information about the modules in the system for troubleshooting
your system.
Table 2-13 Display the current operation information about the modules in the system.
Operation Command Description
Display the current
operation information
about the modules in the
system.
display
diagnostic-information
You can use this
command in any view.
You should execute this
command twice to find the
difference between the
two executing results,
thus helping locate the
problem.