Operation Manual – Cluster
H3C S3600 Series Ethernet Switches-Release 1510 Chapter 1
Cluste
1-9
Operation Command Description
Enable NTDP on
the Ethernet port
ntdp enable
Required
1.2.5 Configuring NTDP-Related Parameters
Table 1-6 Configure NTDP-related parameters
Operation Command Description
Enter system view
system-view
—
Configure the
range to collect
topology
information
ntdp hop hop-value
Optional
By default, the system collects
topology information from the
devices within three hops.
Configure the
device forward
delay of topology
collection requests
ntdp timer hop-delay time
Optional
By default, the device forward
delay is 200 ms.
Configure the port
forward delay of
topology collection
requests
ntdp timer port-delay time
Optional
By default, the port forward
delay is 20 ms.
Configure the
interval to collect
topology
information
periodically
ntdp timer
interval-in-minutes
Optional
By default, the topology
collection interval is one
minute.
Quit system view
quit
—
Start topology
collection
ntdp explore
Optional
1.2.6 Enabling the Cluster Function
Table 1-7 Enable the cluster function
Operation Command Description
Enter system view
system-view
—
Enable the cluster
function globally
cluster enable
Optional
By default, the cluster function
is enabled.