Operation Manual – NTP
H3C S3600 Series Ethernet Switches-Release 1510 Chapter 1
NTP Configuration
1-2
Note:
z The clock stratum determines the accuracy, which ranges from 1 to 16. The stratum
of a reference clock ranges from 1 to 15. The clock accuracy decreases as the
stratum number increases. A stratum 16 clock is in the unsynchronized state and
cannot serve as a reference clock.
z The local clock of an S3600 Ethernet switch cannot operate as a reference clock. It
can serve as a NTP server only after synchronized.
1.1.2 Implementation Principle of NTP
Figure 1-1 shows the implementation principle of NTP.
Ethernet switch A (LS_A) is connected to Ethernet switch B (LS_B) through Ethernet
ports. Both have their own system clocks, and they need to synchronize the clocks of
each other through NTP. To help you to understand the implementation principle, we
suppose that:
z Before the system clocks of LS_A and LS_B are synchronized, the clock of LS_A
is set to 10:00:00 am, and the clock of LS_B is set to 11:00:00 am.
z LS_B serves as the NTP server, that is, the clock of LS_A will be synchronized to
that of LS_B.
z It takes one second to transfer an NTP packet from LS_A to LS_B or from LS_A to
LS_B.

Table of Contents

Other manuals for H3C S3600 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the H3C S3600 Series and is the answer not in the manual?

H3C S3600 Series Specifications

General IconGeneral
BrandH3C
ModelS3600 Series
CategorySwitch
LanguageEnglish

Related product manuals