Operation Manual – SNMP-RMON
H3C S3600 Series Ethernet Switches-Release 1510 Chapter 2
RMON Configuration
2-5
2.3 Displaying RMON
After the above configuration, you can execute the display command in any view to
display the RMON running status, and to verify the configuration.
Table 2-2 Display RMON
Operation Command Description
Display RMON statistics
display rmon statistics
[ interface-type interface-number |
unit unit-number ]
Display RMON history
information
display rmon history
[ interface-type interface-number |
unit unit-number ]
Display RMON alarm
information
display rmon alarm
[ entry-number ]
Display extended RMON
alarm information
display rmon prialarm
[ prialarm-entry-number ]
Display RMON events
display rmon event
[ event-entry ]
Display RMON event logs
display rmon eventlog
[ event-entry ]
These commands
can be executed
in any view.
2.4 RMON Configuration Example
I. Network requirements
z Ensure that the SNMP agents are correctly configured before performing RMON
configuration.
z The switch to be tested has a configuration terminal connected to its console port
and is connected to a remote NMS through Internet. Create an entry in the
Ethernet statistics table to generate statistics on the Ethernet port performance for
network management.