Address Table Commands
155 OL-32830-01 Command Line Interface Reference Guide
5
You can execute the command before the VLAN is created.
Examples
Example 1 - The following example registers the IPv6 address to the bridge table:
switchxxxxxx(config)#
interface vlan
8
switchxxxxxx(config-if)#
bridge multicast ipv6 ip-address
FF00:0:0:0:4:4:4:1
Example 2 - The following example registers the IPv6 address and adds ports
statically.
switchxxxxxx(config)#
interface vlan
8
switchxxxxxx(config-if)#
bridge multicast ipv6 ip-address
FF00:0:0:0:4:4:4:1
add gi11-2
5.11 bridge multicast ipv6 forbidden
ip-address
To forbid adding or removing a specific IPv6 Multicast address to or from specific
ports, use the bridge multicast ipv6 forbidden ip-address Interface (VLAN)
Configuration mode command. To restore the default configuration, use the no
form of this command.
Syntax
bridge multicast ipv6 forbidden ip-address {
ipv6-multicast-address
}
{add |
remove} {ethernet interface-list | port-channel port-channel-list}
no bridge multicast ipv6 forbidden ip-address {
ipv6-multicast-address
}
Parameters
• ipv6-multicast-address—Specifies the group IPv6 Multicast address.
• add—(Optional) Forbids adding ports to the group.
• remove—(Optional) Forbids removing ports from the group.

Table of Contents

Other manuals for Cisco 300 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco 300 Series and is the answer not in the manual?

Cisco 300 Series Specifications

General IconGeneral
ModelCisco 300 Series
CategorySwitch
DimensionsVaries by model
WeightVaries by model
Power over Ethernet (PoE)Available on select models
ManagementWeb-based GUI, SNMP, CLI
VLANsUp to 256
Security FeaturesACLs, 802.1X, Port Security
Humidity10% to 90% non-condensing
Ports8, 16, 24, 48

Related product manuals