1
41.1 rmon alarm
To configure alarm conditions, use the rmon alarm Global Configuration
modecommand. To remove an alarm, use the no form of this command.
Syntax
rmon alarm
index mib-object-id interval rising-threshold falling-threshold
rising-event falling-event [type {absolute | delta}] [startup {rising | rising-falling |
falling}] [owner name]
no rmon alarm
index
Parameters
index—Specifies the alarm index. (Range: 1–65535)
mib-object-id—Specifies the object identifier of the variable to be sampled.
(Valid OID)
interval—Specifies the interval in seconds during which the data is
sampled and compared with rising and falling thresholds. (Range:
1–2147483647)
rising-threshold—Specifies the rising threshold value. (Range:
0–2147483647)
falling-threshold—Specifies the falling threshold value. (Range:
0–2147483647)
rising-event—Specifies the index of the event triggered when a rising
threshold is crossed. (Range: 0–65535)
falling-event—Specifies the index of the event triggered when a falling
threshold is crossed. (Range: 0–65535)