Clock Commands
OL-32830-01 Command Line Interface Reference Guide 250
9
Polling: enabled
Encryption Key: disabled
Broadcast Clients: enabled for IPv4 and IPv6
Anycast Clients: disabled
No Broadcast Interfaces
Source IPv4 interface: vlan 1
Source IPv6 interface: vlan 10
9.22 show sntp status
To display the SNTP servers status, use the show sntp status command in
Privileged EXEC mode.
Syntax
show sntp status
Parameters
N/A
Default Configuration
N/A
Command Mode
Privileged EXEC mode
Example
The following example displays the SNTP servers status:
switchxxxxxx#
show sntp status
Clock is synchronized, stratum 4, reference is 176.1.1.8, unicast
Reference time is afe2525e.70597b34 (00:10:22.438 PDT Jul 5 1993)
Unicast servers:
Server: 176.1.1.8
Source: DHCPv4 on VLAN 1
Status: Up
Last response: 19:58:22.289 PDT Feb 19 2005

Table of Contents

Other manuals for Cisco 300 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco 300 Series and is the answer not in the manual?

Cisco 300 Series Specifications

General IconGeneral
ModelCisco 300 Series
CategorySwitch
DimensionsVaries by model
WeightVaries by model
Power over Ethernet (PoE)Available on select models
ManagementWeb-based GUI, SNMP, CLI
VLANsUp to 256
Security FeaturesACLs, 802.1X, Port Security
Humidity10% to 90% non-condensing
Ports8, 16, 24, 48

Related product manuals