Link Layer Discovery Protocol (LLDP) Commands
OL-32830-01 Command Line Interface Reference Guide 652
30
Parameters
• coordinate
data
—Specifies the location data as coordinates in
hexadecimal format.
• civic-address
data
—Specifies the location data as a civic address in
hexadecimal format.
• ecs-elin
data
—Specifies the location data as an Emergency Call Service
Emergency Location Identification Number (ECS ELIN) in hexadecimal
format.
• data—Specifies the location data in the format defined in ANSI/TIA 1057:
dotted hexadecimal data: Each byte in a hexadecimal character string is
two hexadecimal digits. Bytes are separated by a period or colon. (Length:
coordinate: 16 bytes. Civic-address: 6-160 bytes. Ecs-elin: 10-25 bytes)
Default Configuration
The location is not configured.
Command Mode
Interface (Ethernet) Configuration mode
Example
The following example configures the LLDP MED location information on gi12 as a
civic address.
switchxxxxxx(config)#
interface gi12
switchxxxxxx(config-if)#
lldp med location
civic-address 616263646566
30.10 lldp med network-policy (global)
To define a LLDP MED network policy, use the lldp med network-policy Global
Configuration mode command.For voice applications, it is simpler to use lldp med
network-policy voice auto.
The lldp med network-policy command creates the network policy, which is
attached to a port by lldp med network-policy (interface).
The network policy defines how LLDP packets are constructed.