Operation Manual – Login
H3C S3600 Series Ethernet Switches-Release 1510 Chapter 2 Logging in through the Console Port
2-14
Operation Command Description
Set the maximum
number of lines the
screen can contain
screen-length
screen-length
Optional
By default, the screen can
contain up to 24 lines.
You can use the screen-length
0 command to disable the
function to display information in
pages.
Set history command
buffer size
history-command
max-size value
Optional
The default history command
buffer size is 10. That is, a
history command buffer can
store up to 10 commands by
default.
Set the timeout time for
the user interface
idle-timeout minutes
[ seconds ]
Optional
The default timeout time of a
user interface is 10 minutes.
With the timeout time being 10
minutes, the connection to a
user interface is terminated if no
operation is performed in the
user interface within 10 minutes.
You can use the idle-timeout 0
command to disable the timeout
function.
Note that if you configure to authenticate the users in the scheme mode, the command
level available to users logging into a switch depends on both the
authentication-mode scheme [ command-authorization ] command and the
service-type terminal [ level level ] command, as listed in
Table 2-9.
Table 2-9 Determine the command level
Scenario
Authentication
mode
User type Command
Command level
The service-type
terminal command does
not specify the available
mand level.
com
Level 0
The default
command level of
local users is level 0.
authentication
-mode scheme
[ command-au
thorization ]
Users
logging into
the Console
port and
passing
AAA-RADIU
S or local
authenticati
on
The service-type
terminal command
specifies the available
command level.
Determined by the
command level
specified by the
service-type
terminal command