iPECS eMG80 & eMG800 & UCP
Administration and Programming Manual Issue 1.6
141
3.3.6.24 CRR Attributes – PGM 252
System can reroute incoming call to CO. If called number matched with compare digits of Table
252, the call are routed to Rerouting number.
PROCEDURE:
CRR ATTRIBUTES
PRESS FLEX KEY (1–3)
1. Press the [PGM] button and dial 252.
Press the Flex button 1~3 for the desired setting, refer to
For Flex button 1 enable or disable CRR. For Flex button 2,
press the [Save] button to reset the CRR table. For Flex
button 3, dial the table bin number to input data.
For Flex button 3, Enter the bin number, refer to Table
Table 3.3.6.24-1 CRR ATTRIBUTES (PGM 252)
BTN ATTRIBUTE/DISPLAY DESCRIPTION RANGE DEFAULT
1
ENABLE CRR
(1:ON/0:OFF) : OFF
This field is used to enable or
disable CO Call Rerouting.
0: OFF
1: ON
OFF
2
INIT CRR
PRESS [Save] KEY
This field is used to initialize the
CRR table.
3
CRR ATTRIBUTES
ENTER BIN NO(000-169)
000-169
3-1
CRR 001 COMPARE CO GRP
GRP NO (01-20) : 01
Compared Co group should be
matched with incoming CO group.
01-20
Max 2 digits
01
3-2
CRR 001 RECEIVE DGTS
. . . . . . . . . . . .
Incoming digit numbers should be
matched with these digits. An “*”
may be entered as a wild-card to
indicate insertion of the compared
Max 12 digits
3-3
CRR 001 CO+TEL NUMBER
. . . . . . . . . . . . . . . . . . . . . . . . .
This field defines the CO line, CO
group or CO access code plus
Max 20 digits
3-4
CRR 001 TYPE
. . . . . . .
If you chose ‘1’ for NET type, you
can use transit out code for CO to
CO rerouting. If you chose ‘2’ for
DISA type, you can access the
station number as DISA mode.
Other case, you should not use this
N/A