4.4.13.6 Zone Attribute – PGM 439
Selecting the Zone Attributes returns the Zone Attributes data input page. Enter the desired Zone
number range and click [Load] to assign Zone characteristics. Use the check mark to indicate
which attributes to modify; data for checked attributes is stored by clicking [Save] button.
Figure 4.4.13.6-1 Zone Attributes
The nation code, codec and VMIU/VMIB assigned for a Zone will be employed by all devices in
the Zone unless a different entry is made in Device Zone data. If the Device Zone data is default
or assigned by the MPB, the Zone data will take precedence.
The Zone Attributes define when and which VoIP channels to use for RTP packet relay. Local
VoIP channels are assigned to perform the packet relay function and the use can be defined as “if
needed” or use the assigned RTP Relay Group. For “if Need”, the MPB will employ the IP KTS
STUN protocol to determine when packet relay is required. If assigned “RTP Relay Group”,
packet relay will always be employed for RTP packet receipt.
Table 4.4.13.6-1 ZONE ATTRIBUTES
ATTRIBUTE DESCRIPTION RANGE DEFAULT
Nation Code
Nation code of devices in the zone. Available selections
are given in Country code table.
Country code
E.164 Management Information (Outgoing Dial Number : E164-> Normal) (Incoming CLI Number: Normal -
Area Code
Assign area code that is use to convert CLI format
Max 5 Digits
International
Assign international access code that is use to convert
CLI format (normal <-> E.164)
Max 5 Digits
Local Number Digit
CLI length is over this count then it is long distance call
otherwise it is local call.
00-30 0