Table 4.4.9.9-1 STATION CLASS-OF-SERVICE
STATION
COS
RESTRICTIONS
1
No restrictions are placed on dialing from the station.
2
The assignments in Exception Table A are monitored for allow and deny numbers.
3
The assignments in Exception Table B are monitored for allow and deny numbers.
4
The assignments in both Exception Tables A & B are monitored for allow and deny numbers.
5
The leading digit dialed cannot be a Long Distance code, default “0”, and further
denied/allowed based on Exception Table C.
6
The leading digits dialed cannot be a Long Distance code & digit count cannot exceed the LD
digit counter, default 8 digits, and further denied/allowed based on Exception Table C.
7
Intercom and paging calls are allowed. No outgoing dialing except for emergency calls is
allowed on CO Lines.
8
The assignments in the Exception Table D are monitored for allow and deny numbers.
9
The assignments in the Exception Table E are monitored for allow and deny numbers.
10
The assignments in the Exception Table D & E are monitored for allow and deny numbers.
11
The assignments in the Exception Table A & B and D & E are monitored for allow and deny
numbers.
Table 4.4.9.9-2 STATION/CO LINE COS TOLL RESTRICTIONS
CO COS 1 CO COS 2 CO COS 3 CO COS 4 CO COS 5
STA COS 1
No Restriction No Restriction No Restriction Only Local
Call(LD
code/counter)
and Table C
No Restriction
STA COS 2
Exception Table
A governs the
dialing
Exception Table
A governs the
dialing
No Restriction Only Local
Call(LD
code/counter)
and Table C
No Restriction
STA COS 3
Exception Table
B governs the
dialing
No Restriction Exception Table
B governs the
dialing
Only Local
Call(LD
code/counter)
and Table C
No Restriction
STA COS 4
Exception Table
A & B governs
the dialing
Exception Table
A governs the
dialing
Exception Table
B governs the
dialing
Only Local
Call(LD
code/counter)
and Table C
No Restriction
STA COS 5
Local Call only
(LD Code, “1” or
“0”) and Table C
Local Call only
(LD Code, “1” or
“0”) and Table C
Local Call only
(LD Code, “1” or
“0”) and Table C
Only Local
Call(LD
code/counter)
and Table C
No Restriction
STA COS 6
Only Local Call
(LD code/counter)
and Table C
Only Local Call
(LD
code/counter)
and Table C
Only Local Call
(LD
code/counter)
and Table C
Only Local
Call(LD
code/counter)
and Table C
No Restriction
STA COS 7
In-house dialing
only
In-house dialing
only
In-house dialing
only
In-house dialing
only
In-house dialing
only

Table of Contents