iPECS eMG80 & eMG800 & UCP
Administration and Programming Manual Issue 1.6
119
3.3.6.10 Button LED Flash Rate – PGM 170
The LED flash rate for various functions and states can be assigned any one of the system’s 15
signals. The various functions and states are shown in Table 3.3.6.10-1. The 15 flash signals
available in the system are shown in Table 3.3.6.10-2.
PROCEDURE:
LED FLASHING RATE
PRESS FLEX_KEY (1-24)
1. Press the [PGM] button and dial 170.
LED FLASHING RATE
PRESS FLEX KEY (25-35)
There are 35 Flash rate entries represented by Flex buttons.
To access entries 25 to 35, use the [VOL UP]/[VOL DOWN]
buttons. Press the desired Flex button; refer to Table
Use the dial-pad to enter desired data for the flash rate, refer
to Table 3.3.6.10-1 and Table 3.3.6.10-2.
Press the [Save] button to store the Flash Rate data entry.
Table 3.3.6.10-1 BUTTON LED FLASH RATE (PGM 170)
BTN ATTRIBUTE/DISPLAY DESCRIPTION RANGE DEFAULT
1
COL IN RING
FLASH 30 IPM
CO button Incoming ring flashing
rate.
00-14 FLASH 30
IPM (2)
2
COL XFER RING
FLASH 120 IPM
CO button transfer ring flashing
rate.
00-14 FLASH
120 IPM(10)
3
COL QUE RING
FLASH 240 IPM FLUTTER
CO button queue call back ring
flashing rate.
00-14 FLASH
240 IPM
4
COL RCL RING
FLASH 480 IPM FLUTTER
CO button recall ring flashing rate. 00-14 FLASH
480 IPM
5
COL I HOLD RING
FLASH 30 IPM WINK
CO button I hold flashing rate. 00-14 FLASH 30
IPM WINK(12)
6
COL SYS HOLD RING
FLASH 60 IPM
CO button system hold flashing
rate.
00-14 FLASH 60
IPM (3)
7
COL EXC HOLD RING
FLASH 120 IPM
CO button exclusive hold flashing
rate.
00-14 FLASH
120 IPM(10)
8
COL OUT DISABLED
FLASH 240 IPM FLUTTER
CO button out going disabled
flashing rate.
00-14 FLASH
240 IPM
9
COL IN OFFNET CFW
FLASH 240 IPM FLUTTER
CO button incoming off-net call
forward flashing rate.
00-14 FLASH
240 IPM
10
COL DISA IND
FLASH 240 IPM
CO button DISA indication flashing
rate.
00-14 FLASH
240 IPM(5)