4.4.6.8 Personal Group Attribute - PGM 261
Selecting Personal Group Attribute will display the Personal Group Attribute entry page. Enter a
valid Personal Group number to enter the group data. Click [Save] button after changing Value.
Enter Group Number
: eMG80: 1-70 / eMG800: 1-600 / UCP: 1-1200
Figure 4.4.6.8-1 Personal Group Attributes
Table 4.4.6.8-1 PERSONAL GROUP ATTRIBUTES
ATTRIBUTE DESCRIPTION RANGE DEFAULT
Wake-Up
If this value is set to Overall, all member wake-up
follow by master wake up.
If this value is set to Individual, individual wake-up
is worked by each station.
Individual/
Overall
Individual
Call-Forward
If this value is set to Overall, call forward setting
affect to Master and all members.
If this value is set to Individual, individual Call
Forward is worked by each station.
Individual/
Overall
Overall
Do-Not Disturb
If this value is set to Overall, DND setting affect to
Master and all members.
If this value is set to Individual, individual DND is
worked by each station.
Individual/
Overall
Individual
Linked Pair Mode
If this value is set to ON, Master and Member
Stations are linked and only one station can be
activated.
OFF(Cover Ring)/
ON(Cover Ring
and State Sync.)
OFF(Cover
Ring)