4.4.12 T-NET Data
Selecting the T-NET Data program group returns the sub-menu displayed in the left frame as
shown in the following figure.
Figure 4.4.12-1 T-NET Data Main Page
In a Centralized Control T-NET (Transparent Network), remote devices may be registered to a
Central iPECS system(CM) and to a Local iPECS system (LM). In this way, the CM maintains
control of the remote device. Should the WAN connection between an LM and CM fail (polling
error), the LM will initiate operational control of the locally registered devices. Calls between the
systems (CM and LM) can automatically shift to PSTN Modules registered with the LM for Fail-
over operation. The configuration and characteristics of LMs and CM are configurable as is Fail-
over operation.