iPECS eMG80 & eMG800 & UCP
Administration and Programming Manual Issue 1.6
184
3.3.9.8 System Speed Zone Table PGM 232
The System Speed Dial numbers can be grouped into zones. Only stations allowed can access
numbers within a zone, allowing System Speed Dials to be partitioned. Each zone can be
assigned to apply the appropriate Station and CO Line COS for the Speed Dial number prior to
dialing.
PROCEDURE:
SYSTEM SPEED ZONE PGM
ENTER BIN NO (01-10)
1. Press the [PGM] button and dial 232 and enter the bin
number (Ex.01).
SYSTEM SPEED ZONE 1
F1:ZN F 2:ST F3:TK F4:AK
Using the dial-pad, enter the zone number, 01~10.
Press Flex button 1~3 for the desired zone characteristic,
refer to Table 3.3.9.8-1.
Using the dial pad, enter the desired data as indicated in
Table 3.3.9.8-1.
Press the
[Save]
button to store the data entry.
Table 3.3.9.8-1 SPEED ZONE (PGM 232)
BTN ATTRIBUTE/DISPLAY DESCRIPTION RANGE DEFAULT
1
ENTER NEW ZONE RANGE
ZONE 1 : 2200- 4999
Speed Dial Bin range for zone. 2200-4999 eMG80:2200~4999,
eMG800:2200~9999
2
ENTER STA RANGE
ZONE 1 : 100239
Station range for zone. 100-239 eMG80:100~239,
eMG800:1000~2199
3
SPEED ZONE 1 TOLL CHK
(1:ON/0:OFF) : ON
Assignment to apply toll
restriction.
0: OFF
1: ON
ON
4
SPEED ZONE 1 AUTH CHK
(1:ON/0:OFF) : ON
Speed Dial Authorization Check
for zone.
0: OFF
1: ON
ON