iPECS eMG80 & eMG800 & UCP
Administration and Programming Manual Issue 1.6
128
Table 3.3.6.17-1 SMDR ATTRIBUTES (PGM 177)
BTN ATTRIBUTE/DISPLAY DESCRIPTION RANGE DEFAULT
3
RECORD TYPE
(1 : LD/ 0: ALL) : LD
The system can record all outgoing calls
or only long distance calls. Long
distance calls are identified by the LD
digit count and LD codes assigned in
Flex button 4 and 19, respectively.
0: ALL calls
1: LD
LD
4
LD CALL DIGIT COUNT
(07-15) : 07
Dialed numbers, which exceed the
assigned LD digit count, are considered
long distance calls for SMDR and COS
07-15 07
5
PRINT INCOMING CALL
(1 : ON/ 0: OFF) : OFF
The system can output records for
incoming calls as well as outgoing calls.
If enabled, incoming calls are recorded
as well as outgoing calls.
0: OFF
1: ON
OFF
6
PRINT LOST CALL
(1 : ON/ 0: OFF) : ON
The system can provide lost call records,
records for unanswered incoming
0: OFF
1: ON
ON
7
RECORD IN DETAIL
(1 : ON/ 0: OFF) : ON
The system can output detailed call
records (ON) or summary information
(total number of calls, cost and cost for
0: OFF
1: ON
ON
8
HIDDEN DIALED DIGIT
( 0 – 9 ) : 0
For security purposes, digits dialed for
an outgoing call can be hidden and
replaced with “*”. This field defines the
number of digits to hide.
Button 24 below defines whether leading
or trailing digits are hidden. In addition,
the station must be assigned for SMDR
0~9 0
9
SMDR CURRENCY UNIT
…
The unit of currency used for call cost
can be identified with 3 alpha characters
for easy reference, refer to Table 2.1.2-
-
10
COST PER PULSE
000000
When metering is provided by the PSTN,
the cost per metering pulse can be
6 digits 000000
11
SMDR DECIMAL LOCATION
(0-5) : 0
This value determines the position of the
decimal in the Cost per Pulse, button 10,
starting from the right most digits.
0~5 0
12
SMDR START TIMER (1sec)
(000 – 250) : 000
To allow for call set-up times through the
PSTN, a “Valid call timer” can be set. A
call must be longer than the SMDR Start
Timer for a call record to be generated if
enabled under button 1 above.
000~250
seconds
000
13
SMTP IP ADDR (WEB)
0 . 0 . 0 . 0
SMTP Mail server IPv4 address to
receive the SMDR e-mail reports.
12-digits
14
USER MAIL ADDR (WEB)
…………………………
User e-mail address to receive the
SMDR e-mail reports, display only. To
change data, use Web Admin.