Table 3.3.7.2-1 STATION GROUP ATTRIBUTES CIRCULAR & TERMINAL GROUPS
(PGM 191)
BTN ATTRIBUTE/DISPLAY DESCRIPTION RANGE DEFAULT
9
CIRC 401 WRAP-UP TMR
(000 - 999) : 002
After terminating any call, a Group
member will be maintained in a
busy state for the duration of the
WRAP-UP Timer.
000~999
(seconds)
002
10
CIRC 401 NO ANS TMR(1s)
(00 99) : 15
Calls to a station in the group are
directed to the station, if
unavailable or unanswered in the
NO Answer Timer, the call can be
routed based on the assigned hunt
process.
00~99
(seconds)
15
11
CIRC 401 PILOT HUNT
(1 : ON/ 0: OFF) : ON
A circular/terminal hunt group can
be set so that only calls to the pilot
number (Station Group number)
will hunt.
0: OFF
1: ON
ON
12
CIRC 401 RPT NO MEMBER
(1 : ON/ 0: OFF) : OFF
If a call is received and no
members are on-duty, an ICM call
will return re-order tone, while a
CO/IP call will be routed to the
overflow destination.
0: OFF
1: ON
OFF
13
CIRC 401 MUSIC SRC
(0010) : 01
A Music source is assigned so that
calls to the group receive audio
from the source in place of ring-
back tone.
00: Ring-back
01: INT Music
02: EXT Music
03: VSF MOH
04: SLT MOH1
05: SLT MOH2
06: SLT MOH3
07: SLT MOH4
08: SLT MOH5
09: VSF MOH2
10: VSF MOH3
01
14
CIRC 401 MBR FORWARD
(1 : ON/ 0: OFF) : ON
A member activating Call forward
may be placed in an unavailable
state for hunt group calls (ON).
When OFF, group calls are sent to
the member as normal.
0: OFF
1: ON
ON
15
MAILBOX MSG WAIT STA
. . . .
When a group calls overflows or
routes to the VM group, a station
number is used to identify the
Mailbox for the Circular group
messages.
Station ….
16
MAILBOX PASSWORD
…………
The password associated with a
group Mailbox is defined here.
The password is used in
conjunction with the Circular group
as with a normal station.
12 digits ….