iPECS eMG80 & eMG800 & UCP
Administration and Programming Manual Issue 1.6
235
4.3.5.2 Nation Code
During initialization, the system employs the Nation Code to establish the default gains and tones
for the various interfaces (analog CO Lines, ISDN lines, etc.), as well as the numbering plans for
the specific country. The gains, in particular must be set to comply with the local regulatory
requirements. Normally, the Nation Code will be set at the factory, however, assure the Nation
code matches the system location.
1) Dip Switch pole 4 of UCP100 (or UCP600, UCP2400) moves to ON. Dip Switch pole 2 of
KSU (eMG) moves to ON.
Changing Nation Code
2) Change Nation Code by clicking in the combo box.
3) Click [Save] button and then the system start resetting to apply.
In addition, all other data will be initialized, so the Nation Code should be properly set prior to
other programming. You can change the numbering plan for your situation.
Figure 4.3.5.2-1 Set Nation Code Wizard
4.3.5.3 Set System Time and Date
You can set System time and date in this page.
Figure 4.3.5.3-1 Set system time and date