iPECS eMG80 & eMG800 & UCP
Administration and Programming Manual Issue 1.6
565
4.4.16.2 DECT ATTRIBUTES - PGM 491
Selecting the DECT Attributes returns the DECT ATTRIBUTES input page. Click [Save] button
after changing Value.
Figure 4.4.16.2-1 DECT ATTRIBUTES
DECT Attributes define functions associated with the DECT equipment and operation as shown
in the following table.
Table 4.4.16.2-1 DECT Attributes
ATTRIBUTE DESCRIPTION RANGE DEFAULT
Auto Call Release
If enabled, when the other party of an active internal call
disconnects, DECT terminal returns to idle.
OFF
ON
OFF
Base Fault Alarm
If enabled, DECT Base station alarms are sent to the
Attendant.
Disable
Enable
Disable
Chain Fault Alarm
If enabled, alarms are sent to the Attendant indicating a
fault in the link between WTIM modules. This feature is
only for UCP.
Disable
Enable
Disable
Handover
Sensitivity (GDC-
500H only)
The user can control the handover sensitivity of GDC-
500H. (Normal or Strong)
If this value is changed, all WTIBs will restart.
Normal
Strong
Normal