iPECS UCP - TNET (Centralized Networking) - PGM 330 ~ 336; TNET Basic Attributes - PGM 330

iPECS UCP
689 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
iPECS eMG80 & eMG800 & UCP
Administration and Programming Manual Issue 1.6
200
3.3.11 TNET (Centralized Networking) PGM 330 ~ 336
In a Centralized Control TNET (Transparent Networking), remote devices may be registered to a
Central MPB/MPB (CM) and to a Local MPB/MPB (LM). In this way, the CM maintains control of
the remote device. Should the WAN connection between an LM and CM fail (2 second polling
error), the LM will initiate operational control of the locally registered devices. Calls between the
systems (CM & LM) can automatically shift to PSTN Modules registered with the LM for Fail-over
operation. The configuration and characteristics of LMs and CM are configurable as is Fail-over
operation.
3.3.11.1 TNET Basic Attributes PGM 330
Each MPB in a Central Control network environment must be enabled for TNET operation in
order to function as part of the network.
PROCEDURE:
TNET BASIC ATTRIBUTES
PRESS FLEX KEY (1 1)
1. Press the [PGM] button and dial 330.
TNET ENABLE
(1:ON/0:OFF) : OFF
Press Flex button 1.
Use the dial-pad to enable or disable TNET, Central Control
networking.
Press the [Save] button to store the new data.