62
3.3.3.12 Station Timers PGM 123
Certain timers can be assigned on a station basis. Available timers, description and valid inputs
are given in Table 3.3.3.12-1.
PROCEDURE:
STATION TIMERS
ENTER STA RANGE
1. Press the [PGM] button and dial 123.
100-110 STATION RANGE
PRESS FLEX KEY (1-2)
Use the dial-pad to enter a station range (Ex. 100~110). For
a single station, enter the same number twice.
Press the desired Flex button.
Use the dial-pad to enter desired data for the Station IP
Attribute, refer to Table 3.3.3.12-1.
Press the
[Save]
button to store the data entry.
Table 3.3.3.12-1 STATION TIMERS (PGM 123)
BTN ATTRIBUTE/DISPLAY DESCRIPTION RANGE DEFAULT
1
STA FWD NO ANS TMR (sec)
(000-600) : 000
This timer determines the
duration the station will ring prior
to Ring-No-Answer Forward.
This setting affects both manual
and Preset Call Forward and
overrides the System Ring No
Answer timer PGM 181-button
1.
000-600
seconds
000
2
CUT OFF (Min)
(00-99) : 00
Allowed length of CO/IP calls
when station is assigned Call
Time restriction in Station
Attributes II, PGM 112, button 3
00-99
minutes
00