EasyManua.ls Logo

iPECS UCP - 2.7.12.5 Supervisor Help Response

iPECS UCP
689 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
iPECS eMG80 & eMG800 & UCP
Administration and Programming Manual Issue 1.6
36
3.3.3 Station Data PGM 110-125
3.3.3.1 Station Type -PGM 110
Each station is assigned a type, which is used by the system to recognize the station‘s
capabilities and default Flex button configuration. In addition, for the iPECS DSS/BLF Consoles,
the associated station number is identified here. Note that the maximum of three (3) DSS
Consoles(LIP DSS & LDP DSS) can be associated and connected to a station.
PROCEDURE:
STATION TYPE ASSIGN
ENTER STA RANGE
1. Press the [PGM] button and dial 110.
100-110 F1:TY F2:ASC
IPKTU
Use the dial-pad to enter a station range (Ex 100~110). For
a single station, enter the same number twice; use this
procedure for an iPECS DSS Console.
Select Flex button 1, to set the station type and, for iPECS
DSS Consoles (types 2~4), Flex button 2 assigns the
associated station.
100-110 F1:TY F2:ASC
IPKTU
Use the dial-pad to enter desired data:
4-1. For Flex button 1 (TYPE), enter the station TYPE;
refer to Table 3.3.3.11.
111-111 F1:TYPE F2 :ASC
DSS MAP2 : STA . . . .
4-2. For Flex button 2 (Associated station), enter the
number of the station used with the console. Flex button
2 is only available for iPECS DSS Consoles (Types 2~4),
see Table 3.3.3.1-2 for default configurations.
Press the [Save] button to store the data entries.
Table 3.3.3.1-1 STATION TYPE ASSIGNMENT (PGM 110)
TYPE DESCRIPTION
1
IP KEYSET
2
DSS MAP 1
3
DSS MAP 2
4
DSS MAP 3
5
SLT (DTMF)
6
SLT (DTMF) Voltage Message lamp
7
SLT (DTMF) FSK Message lamp
8
SLT (DTMF) Polarity Reversal Message lamp

Table of Contents

Other manuals for iPECS UCP