iPECS eMG80 & eMG800 & UCP
Administration and Programming Manual Issue 1.6
36
3.3.3 Station Data –PGM 110-125
3.3.3.1 Station Type -PGM 110
Each station is assigned a type, which is used by the system to recognize the station‘s
capabilities and default Flex button configuration. In addition, for the iPECS DSS/BLF Consoles,
the associated station number is identified here. Note that the maximum of three (3) DSS
Consoles(LIP DSS & LDP DSS) can be associated and connected to a station.
PROCEDURE:
STATION TYPE ASSIGN
ENTER STA RANGE
1. Press the [PGM] button and dial 110.
100-110 F1:TY F2:ASC
IPKTU
Use the dial-pad to enter a station range (Ex 100~110). For
a single station, enter the same number twice; use this
procedure for an iPECS DSS Console.
Select Flex button 1, to set the station type and, for iPECS
DSS Consoles (types 2~4), Flex button 2 assigns the
associated station.
100-110 F1:TY F2:ASC
IPKTU
Use the dial-pad to enter desired data:
4-1. For Flex button 1 (TYPE), enter the station TYPE;
refer to Table 3.3.3.1–1.
111-111 F1:TYPE F2 :ASC
DSS MAP2 : STA . . . .
4-2. For Flex button 2 (Associated station), enter the
number of the station used with the console. Flex button
2 is only available for iPECS DSS Consoles (Types 2~4),
see Table 3.3.3.1-2 for default configurations.
Press the [Save] button to store the data entries.
Table 3.3.3.1-1 STATION TYPE ASSIGNMENT — (PGM 110)
TYPE DESCRIPTION
1
2
3
4
5
6
SLT (DTMF) – Voltage Message lamp
7
SLT (DTMF) – FSK Message lamp
8
SLT (DTMF) – Polarity Reversal Message lamp