72
3.3.4.2 T1/E1/PRI Attributes PGM 131
Each T1/PRI module can be assigned for various attributes of the interface. The T1 interface
framing and line coding can be selected and, for the PRI, TE or NT operation and CRC check can
be selected. Refer to Table 3.3.4.2-1 for a description of the features and the input required. Note
that the Sequence Number can be determined in PGM 103, Button 1.
PROCEDURE:
T1 /E1/PRI ATTRIBUTE
ENTER SEQ NO ( 001 300 )
1. Press the [PGM] button and dial 131 and enter sequence
number (Ex. 001). eMG800 range is 0001-2890.
001 T1 /PRI ATTR
PRESS FLEX KEY ( 1 – 7 )
Use the dial pad to enter the Sequence Number of the
desired T1/PRI module. Use PGM 103 to determine
Sequence Numbers. (e.g. enter the sequence number
Press the desired Flex button; refer to Table 3.3.4.2-1.
Use the dial pad to enter the desired data, refer to Table
3.3.4.2-1.
Press the
[Save]
button to store the Table data entry.
Table 3.3.4.2-1 T1/PRI MODE (PGM 131)
BTN ATTRIBUTE/DISPLAY DESCRIPTION RANGE DEFAULT
1
T1 SETUP MODE
(1:ESF/0:D4) : D4
Select T1 Setup mode.
D4 frame: Use In-Band Control
Protocol.
ESF: Use Data link Message.
0: D4
1: ESF
D4
2
T1 LINE MODE
(1:AMI/0:B8ZS) : B8ZS
Select T1 line mode (AMI/B8ZS). 0: B8ZS
1: AMI
B8ZS
3
PRI LINE MODE
(1:TE/0:NT): TE
Select TE/NT mode. 0: NT
1: TE
TE
4
PRI/E1 CRC CHECK
(1:ON/0:OFF): OFF
For PRI lines the CRC (Cyclical
Redundancy Check) can be
disabled (OFF).
0: OFF
1: ON
OFF
5
E1 R2DSP CHECK
(1:ON/0:OFF): OFF
Used for R2-El board or E1 board. 0: OFF
1: ON
OFF
6
DCO PX TYPE
(0-3): STANDARD (2)
Reserved for future use with R2 E1
board.
0: S1240
1: TDX1B
2: STANDARD
3:CONGES_DIS
STANDARD
7
CALLER NAME TYPE
(1:DISP/0:FAC) : FACILIT
If the caller has a name, the Caller
Name is sent to the network
according to the option (FACILITY,
DISPLAY). (USA only)
0:FACILITY
1:DISPLAY
FACILITY