iPECS eMG80 & eMG800 & UCP
Administration and Programming Manual Issue 1.6
405
4.4.5.37 PPP Attributes for eMG – PGM 205
Selecting PPP Attributes will display the PPP Attributes data entry page. Use the check mark to
indicate which attributes to modify; data for checked attributes is stored by clicking [Save] button.
Figure 4.4.5.37-1 PPP Attributes
In addition to remote access via an IP network connection, the system database may be
accessed remotely via an ISDN connection. Placing a call over an ISDN Line to the designated
PPP Station will provide a connection to the system database. The system will request a user id
and password, which must match one of the User Ids and passwords assigned. After a matching
id and password are received, the iPECS Login Home page is provided.
Table 4.4.5.37-1 PPP ATTRIBUTES
ATTRIBUTE DESCRIPTION RANGE DEFAULT
The System accepts this PPP ID 1 as valid.
The password entered is used to authorize PPP ID 1.
User ID 2 The System accepts this PPP ID 2 as valid. Max. 12 characters likppp02
The password entered is used to authorize PPP ID 2.
PPP Server IP
When configured, the PPP Server IP Address must match
this entry. To apply this option the system must be restarted.
IP Address
PPP Client IP Addr
When configured, the PPP Client IP Address must match
this entry. To apply this option the system must be restarted.
IP Address