EasyManua.ls Logo

iPECS UCP - 2.80.2.4 Network Call back (Call Completion)

iPECS UCP
689 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
iPECS eMG80 & eMG800 & UCP
Administration and Programming Manual Issue 1.6
233
4.3.3 iPECS Web Page Navigation
The Navigation frame appears in the left after login; refer to Figure 4.3-1. Selecting a Program
group from either the Navigation pane or the Favorites list will display the selected Web entry
page.
Each of the system‘s data entry Web pages includes a frame for data display and modification.
To modify data, click in the data field, either a drop-down menu will appear for entry selection or a
cursor will appear in the field and the user may type in the data required. Once all new data for a
Web page has been entered, the [Save] button must be clicked to send the new page to the
system and save the modified data.
In some cases, where mentioned, it may be necessary to reset the system. The system can be
reset manually as described in the iPECS Hardware Description and Installation Manual by
selecting the Reset System button on the Initialization Web page or using the reset button.
4.3.4 General Web Page Features
4.3.4.1 Web Page Range Entries
On many of the Web pages for Station, CO Line and Tables Data a range of station, lines or table
indices must be entered to display the appropriate data entry page. In this case, a range of
devices or indices can be selected by entering the lowest and highest device number separated
by a dash. In addition, a comma can be used to enter non-sequential numbers. Note no space
characters should be entered before or after the dash or comma. Note the data entry page
displays the data for the lowest device or table index entered.
4.3.4.2 Table Check Boxes
Data entry pages that require a range entry, only display the data for the lowest device number or
Table index entered in the range. To assure that only the appropriate data is changed for all
entries in the range, a check box is located in front of each attribute. When the page is saved,
only data for attributes with the box checked are saved for the range while data for unchecked
attributes are not modified.
4.3.4.3 Sorting Displayed Data
Charts in the data pages typically allow the data to be sorted based on a given column in either
ascending or descending order. In the column header, the sorting symbol displays to indicate the
sorting function is available for the column.

Table of Contents

Other manuals for iPECS UCP

Related product manuals