iPECS eMG80 & eMG800 & UCP
Administration and Programming Manual Issue 1.6
531
4.4.12.6 T-NET Music/Alarm -PGM 335 ~ 336
Selecting T-NET Music/Alarm will display the data entry page. Enter the T-NET range from the T-
Net LM Attributes then click [Load] to modify the data. Click [Save] button after changing Value.
Enter T-NET Range
: eMG80: 1-15 / eMG800: 1-32 / UCP: 1-100
Figure 4.4.12.6-1 T-NET Music/Alarm
To minimize WAN traffic, the CM does not provide BGM/MOH to an LM. The LM employs local
BGM and MOH facilities to reduce traffic load on the WAN and IP channel processors. The LM
uses IP Multicast for local BGM and MOH transport. In addition, the Alarm contacts of the LM can
be defined for use as a local alarm or doorbell.
When alarm port 1 of the LM is activated, the string of {Alarm 1 Display} is displayed in assigned
stations.
When alarm port 2 of the LM is activated, the string of {Alarm 2 Display} is displayed in assigned
stations (if LM is UCP600/2400).