Table 3.3.8.7-1 Prefix Dialing Table (PGM 206)
BTN ATTRIBUTE/DISPLAY DESCRIPTION RANGE DEFAULT
6
001 NUM PLAN(0-6)
UNKNOWN(0)
Select Numbering Plan (0~6).
Unknown/ISDN/Data
Numbering/Telex/National
Standard/Private /Reserved
0-6
(0:Unknonw
1:ISDN/Telephony
2:Data numbering
3:Telex
4:National
standard
5:Private
6:Reserved)
UNKNOWN(0)
7
001 SENDING COMPLETE
(1:ON/0:OFF) : OFF
Select Sending Complete option.
(On/Off)
0-1 OFF
8
001 CALL TYPE (0-5)
UNKNOWN(0)
Call Charge Type (0~5).
Unknown/Local/Long Distance/
International/Mobile/reserved
0-5
(0:Unknown
1:Local
2:Long Distance
3:International
4:Mobile
5:reserved)
UNKNOWN(0)
9
001 CALL TIMER(sec)
(000 999) : 000
Call Charge Timer can be
assigned. By this timer value Call
Metering can be established.
000-999 000
10
001 CALL COST
000000
Call Cost is calculated by CALL
TIMER. (ex : timer is 1 min, cost is
000020, then after 3 minute call,
total call cost is calculated to
000060)
000000-999999 000000
11
001 FLAT RATE
(1:ON/0:OFF) : OFF
If Flat Rate is ON, Flat Rate is
applied by CALL COST per a call
0-1 OFF
12
PREFIX TABLE INIT
PRESS [HOLD] TO INIT
Initialize Prefix table.