EasyManua.ls Logo

iPECS UCP - 4.17 Multiple Calling Line IDs

iPECS UCP
689 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
iPECS eMG80 & eMG800 & UCP
Administration and Programming Manual Issue 1.6
322
Table 4.4.4.2-1 Analog ATTRIBUTES
ATTRIBUTE DESCRIPTION RANGE DEFAULT
recognized as a “Disconnect Signal”.
(*100 msec)
ICLID Ring Timer
When a call is received, the system may use ICLID
(Incoming Caller ID) to route the call. The system
will delay routing a call for this duration while
awaiting ICLID. Enter a 00 to disable ICLID routing.
00-20
(*Sec)
4
Proctor Service
Each analog CO line can be assigned to send the
station number as DTMF digits for Proctor service.
OFF
ON
OFF
Analog Line monitor
The system can monitor and report faults on an
analog CO Line.
OFF
ON
ON
LD Inter Digit Timer
This time is for setting the duration between digits
for LD (Long Distance) call.
00-20 (*1sec) 0
LD Pause count
This count sets the number of Pause for Long
distance call.
0-10 0
Table 4.4.4.2-2 CALL METERING FUNCTION
ENTRY SMDR METERING UNIT TYPE
00
- None
01
- 50 Hz
02
- 12 KHz
03
- 16 KHz
04
- Singular Polarity Reverse (SPR)
05
- Plural Polarity Reverse (PPR)
06
- No Polarity Reverse (NPR)

Table of Contents

Other manuals for iPECS UCP