Table 4.4.4.2-1 Analog ATTRIBUTES
ATTRIBUTE DESCRIPTION RANGE DEFAULT
recognized as a “Disconnect Signal”.
ICLID Ring Timer
When a call is received, the system may use ICLID
(Incoming Caller ID) to route the call. The system
will delay routing a call for this duration while
awaiting ICLID. Enter a 00 to disable ICLID routing.
00-20
(*Sec)
4
Proctor Service
Each analog CO line can be assigned to send the
station number as DTMF digits for Proctor service.
OFF
ON
OFF
Analog Line monitor
The system can monitor and report faults on an
OFF
ON
LD Inter Digit Timer
This time is for setting the duration between digits
for LD (Long Distance) call.
00-20 (*1sec) 0
LD Pause count
This count sets the number of Pause for Long
0-10 0
Table 4.4.4.2-2 CALL METERING FUNCTION
ENTRY SMDR METERING UNIT TYPE
- Singular Polarity Reverse (SPR)
- Plural Polarity Reverse (PPR)
- No Polarity Reverse (NPR)