338
Table 4.4.4.12-1 T1 CO LINE ATTRIBUTES
ATTRIBUTE DESCRIPTION RANGE DEFAULT
60-40(20pps)
66-33(20pps)
SEZ DTC This timer defines the length of a valid ‘line seizure’ signal.
0~127
(20 ms)
3
RELEASE
For Ground Start, this timer defines the minimum length of
time ground will not be applied to the TIP side from the
PSTN.
0~127
(20 ms)
7
IASG TY
Incoming Address Signaling Type defines the type of
signaling (DTMF or Pulse) expected.
PULSE/
DTMF
DTMF
RING DTC
The Ring DTC (detect) timer defines the minimum
acceptable length of the Ring-on time during a ring cycle.
2~9
(100 ms)
2
RING STOP
The Ring Stop timer defines the maximum Ring-off time
during a ring cycle.
10~60
(100 ms)
60
COLLECT DGT
Collect DGT (digits) defines the number of digits expected
on a DID line.
1~6 3
STORE TIME
For DID lines, this timer defines the maximum delay
between incoming DID digits.
1~15
(second)
15