Table 4.4.4.1-2 STATION/CO LINE TOLL RESTRICTIONS
CO COS 1 CO COS 2 CO COS 3 CO COS 4 CO COS 5
STA
COS 1
No Restriction No Restriction No Restriction Only Local Call (LD
code/counter) & Table C
No
Restriction
STA
COS 2
Exception Table A
governs the dialing
Exception Table A
governs the dialing
No Restriction Only Local Call (LD
code/counter) & Table C
No
Restriction
STA
COS 3
Exception Table B
governs the dialing
No Restriction Exception Table B
governs the
dialing
Only Local Call (LD
code/counter) & Table C
No
Restriction
STA
COS 4
Exception Table A &
B governs the dialing
Exception Table A
governs the dialing
Exception Table B
governs the
dialing
Only Local Call (LD
code/counter) & Table C
No
Restriction
STA
COS 5
Local Call only (LD
Code, “1” or 0”) and
Table C
Local Call only (LD
Code, “1” or “0”)
and Table C
Local Call only
(LD Code, “1” or
“0”) & Table C
Only Local Call (LD
code/counter) & Table C
No
Restriction
STA
COS 6
Only Local Call (LD
code/counter) &
Table C
Only Local Call (LD
code/counter) and
Table C
Only Local Call
(LD code/counter)
& Table C
Only Local Call (LD
code/counter) & Table C
No
Restriction
STA
COS 7
In-house dialing only In-house dialing
only
In-house dialing
only
In-house dialing only In-house
dialing only
STA
COS 8
Exception Table D
governs the dialing
Exception Table D
governs the dialing
No Restriction Only Local Call (LD
code/counter) & Table C
No
Restriction
STA
COS 9
Exception Table D
governs the dialing
Exception Table D
governs the dialing
No Restriction Only Local Call (LD
code/counter) & Table C
No
Restriction
STA
COS 10
Exception Table D &
E governs the dialing
Exception Table D
& E governs the
dialing
No Restriction Only Local Call (LD
code/counter) & Table C
No
Restriction
STA
COS 11
Exception Table A &
B and D & E governs
the dialing
Exception Table A
& B and D & E
governs the dialing
No Restriction Only Local Call (LD
code/counter) & Table C
No
Restriction
Table 4.4.4.1-3 CALL METERING FUNCTION
ENTRY CALL METERING TYPE
00
- None
01
- 50 Hz
02
- 12 KHz
03
- 16 KHz
04
- Singular Polarity Reverse (SPR)
05
- Plural Polarity Reverse (PPR)
06
- No Polarity Reverse (NPR)