Table 4.4.5.17-1 SMDR ATTRIBUTES
ATTRIBUTE DESCRIPTION RANGE DEFAULT
SMDR ICM Save
When enabled, intercom call data is stored as part of the
OFF
OFF
SMDR ICM Print
When enabled, intercom call data is printed as part of the On-
OFF
OFF
SMDR Disconnect
When enabled, the disconnect cause is stored in Off-line
SMDR data and printed as parted of the On-line SMDR.
OFF
OFF
Long time call
To monitor long duration external calls, a “Long Time Call” can
be set. If CO call duration exceeds this value, a notification will
be sent to NMS server and alarm. If set to “000” the feature is
000 ~ 144
(10 min.)
0
Print SMDR from any
When a CO call is transferred to a Net transit-out CO, the local
OFF
OFF
Transfer Call Charge
Rate
When a call is transferred by a station, the SMDR record can
be charged based on the following options.
1. Individual: When a call is transferred to another station, the
transferred call is charged both stations based on the time on
the call.
2. Integrate transferring station: When a call is transferred to
another station, the call is charged to the transferring station.
3. Integrate transferred station: When a call is transferred to
another station, the call is charged to the station receiving the
Individual/
Integrate
transferring
station/
Integrate
transferred
station
Individual
Station
Attendant Transfer
Charge Rate
When a call is transferred by a station, the SMDR record can
be charged based on the following options.
1. Individual charging: When the Attendant places an outgoing
call and transfers the call to a station, the Transfer Call
Charge Rate above.
2. Attendant station charging: When Attendant places an
outgoing call and transfers this call to a station, the call is
charged to the Attendant.
3. Transferred station charging: When the Attendant places an
outgoing call and transfers this call to a station, the call is
charged to the receiving station.
Individual
charging/
Attendant
station
charging/
Transferred
station
charging
Individual
charging
International Access
Code
The system will recognize the digits assigned as the
International access code digit sequence when dialed as the
Max. 4 digits
Mobile Access Code
The system will recognize the digits assigned as the Mobile
network access code digit sequence when dialed as the first
Max. 4 digits
VSF Voicemail
indication
Calls to the Voice Mail may be shown as I (Incoming call) or V
(New indication) for Voice Mail in the SMDR record.
I (Incoming
call)/
V (New
I(Incoming
call)
Display Nxxxx for Net
number
An “N” can be included in the SMDR to identify the call as a
OFF/
OFF
Outgoing call type
Select SMDR type for outgoing call.
- All call: SMDR can be provided for all outgoing call.
- Answered call: SMDR can be provided in case the called
All Call,
Answered Call
All Call