iPECS eMG80 & eMG800 & UCP
Administration and Programming Manual Issue 1.6
382
Table 4.4.5.20-1 SYSTEM TIMERS
ATTRIBUTE DESCRIPTION RANGE DEFAULT
I-Hold Recall Timer
Enter the desired time for Hold recall. The station
receives the call again after a specified time.
000~600
030
System Hold Recall
Enter the desired time for System hold recall time. The
station receives the call again after a specified time.
000~600
030
Transfer Recall Timer
Enter the desired time for transferring the call again to
000~600
030
ACNR Delay Timer
If the ACNR Pause Timer expires and no CO/IP Line is
available for ACNR recall, in this filed, you can set the
delay time before ACNR attempts to access a CO/IP
line again. This feature doesn’t affect the ACNR retry
000~300
(seconds)
030
ACNR Pause Timer
Enter the desired time for pause between ACNR recall
000~300
030
ACNR Retry Counter
Enter the number of ACNR retry attempts. ACNR will
finish after a specified times.
Regarding CIS country, the range is from 1 to 9.
1~13 03
ACNR Tone Detect
Timer
If call progress tones are not available for ACNR, the
system will wait the specified time after dialing before
considering the called party as “busy/no answer”.
001~300
(seconds)
30
Automatic CO Release
Timer
If a user accesses a CO/IP Line and takes no action,
the system will automatically release the CO/IP Line
when the specified time is over or expired.
000~300
(seconds)
030
CCR Inter-digit Timer
Inter-digit timer used with Customer Call Routing
000~300
030
CO Dial Delay Timer
To prevent dialing when CO/PBX has slow response,
dialing by the system can be delayed using this timer.
00~99
05
CO Release Guard
Timer
When a CO/IP Line is returned to idle, the system will
deny access for the specified time to assure the PSTN
returns the CO/IP Line circuitry to be idle.
010~150
(seconds)
020
CO Ring Off Timer
This timer sets the maximum ‘OFF’ duration of the
incoming ring cycle for the Ring Detect circuitry of the
system to detect an abandoned call.
001~150
(seconds)
060
CO Ring ON Timer
This timer sets the ‘ON’ time of the incoming ring cycle
for the Ring Detect circuitry of the system to recognize
1~9
(100 msec)
2
Elapsed Call Timer
Users can receive a periodic tone indicating the length
of an outgoing call. This timer sets the time before and
between the tones. Note CO Warning Tone must be
enabled for the station in Station Data in ‘Station Data
005~900
(seconds)
180
Web Password Guard
Timer
If no data packet is received during a Web connection,
after the guard time a password check will be initiated
001~999
(minutes)
5
Call Forward No
Answer Timer
When a user activates No-Answer Forward, calls will
ring for this duration before being forward. The Station
No-Answer Forward timer section will take precedence.
000~600
(seconds)
15
DID/DISA No Answer
Timer
A DID/DISA call to a busy station will forward to the
DID/DISA Destination assigned under section should
000~255
(seconds)
00